Skip to content
CAAS Workstation

CAAS Workstation

Quantitative Coronary and Vascular Analysis in the Catheterisation Laboratory

Functions for quantification of coronary and peripheral arteries, analysis of the left and right ventricle, enhanced stent visualisation and calculation of the vFFR value.

CAAS vFFR 3D reconstruction coronary artery with vFFR value
3D model and vFFR value
CAAS vFFR pullback pressure gradient along the coronary artery
vFFR pullback along the vessel course
CAAS vFFR anatomical measurement results stenosis and reference diameter
Anatomical lesion information
CAAS vFFR · Virtual Fractional Flow Reserve

Functional Lesion Assessment without Pressure Wire and without Adenosine

5x faster than FFR
94% diagnostic accuracy
r=0,95 reproducibility
Non-inferior to FFR · FAST III
CAAS vFFR
  • Functional lesion assessment using only two angiograms and aortic pressure
  • No pressure wire, no adenosine, no hyperaemia
  • Rapid anatomical and physiological results
  • 3D reconstruction and vFFR value as cut-off
  • Treatment planning through stent placement and residual vFFR
  • Manufacturer-independent, compatible with most X-ray systems
Clinical Validation · FAST III
2.235patients
37centres
7countries
7countries
NEJM 2026publication

Multicentre, randomised, non-inferior to FFR. MACE at one year identical (7.5% vs. 7.5%).

"The results of FAST III confirm the safety and feasibility of the online use of vFFR as an easy to use minimally invasive tool to guide revascularization in patients with intermediate coronary artery lesions."

Dr. Joost Daemen — Principal Investigator FAST III, Erasmus Medical Center Rotterdam

Request demo
CAAS QCA · Quantitative Coronary Analysis

QCA enables quantification of stenoses in single and bifurcated vessels

Assessment of coronary artery dimensions and quantification of stenosis in single and branched vessels. QCA supports selection of the optimal balloon or stent size during percutaneous coronary intervention (PCI).

Analysis of
  • Obstructions
  • Local diameters
  • Complete occlusions
Request demo
CAAS QCA Workstation coronary analysis with stenosis measurement
QCA stenosis quantification
CAAS QVA · Quantitative Vascular Analysis

Fast and intuitive analysis of peripheral vessels to support diagnosis and therapy

Areas of application
  • Abdominal aorta
  • Carotid arteries
  • Renal arteries
  • Iliac arteries
  • Femoral arteries
Analysis of individual vessels including
  • Calibration
  • Contour detection
  • Quantification of lesion length and stenosis severity in %
Request demo
CAAS LVA · RVA · Ventricular Analysis

Angiography-based ventricular analysis

Measurement of ventricular volumes, ejection fraction, stroke volume, cardiac output and wall motion.

LVA
  • Multiple wall motion analyses
RVA
  • Seven models for calculation of ventricular volume
Request demo
CAAS IV-LINQ · IVUS and OCT Co-registration

Real-time co-registration of IVUS and OCT with angiography

IV-LINQ enables real-time co-registration between angiography and IVUS/OCT, providing a detailed overview of lesions and their precise location within the coronary artery tree.

  • Co-registration in real time
  • Manufacturer-independent
  • Diameter and area measurements for IVUS/OCT
Request demo
CAAS StentEnhancer · Stent Visualisation

Automated stent visualisation

  • Rapid assessment of stent expansion
  • Verification of correct stent placement
  • Assessment of stent-in-stent placement
Request demo
QCA Research · Extended Coronary Analysis

Specialised analysis functions for clinical studies

QCA Research extends the standard QCA workflow with dedicated functions for research designs. Drug eluting stent analysis, user-defined subsegments and specialised bifurcation models enable precise longitudinal analyses in multicentre studies.

Analysis functions
  • Drug eluting stent analysis with restenosis and edge effects in pre-, post- and follow-up studies
  • User-defined subsegment analysis with up to six subsegments
  • Bifurcation analysis using the six- and eleven-segment model for implanted bifurcation stents
Request demo
QVA Research · Extended Peripheral Vascular Analysis

Research functions for peripheral intervention studies

QVA Research extends the peripheral vascular analysis workflow with functions for clinical studies. Restenosis and edge effect assessment for drug eluting stents as well as subsegment analyses enable reproducible longitudinal investigations in multicentre designs.

Analysis functions
  • Drug eluting stent analysis with restenosis and edge effects in pre-, post- and follow-up studies
  • Drug eluting balloon analysis for assessment of overlap zones
  • User-defined subsegment analysis for independent segment assessments
Request demo
The complete software platform

Planning and analysis from a single source

Die CAAS Workstation ist Teil eines umfassenden Portfolios für die kardiovaskuläre Bildanalyse. Für centres, die neben der Katheterdiagnostik auch strukturelle Herzeingriffe oder endovaskuläre Gefäßversorgung planen, stehen spezialisierte Module auf derselben Plattform bereit.

Your benefits

One system. One training. One partner.

All CAAS Workstation modules and the 3mensio modules run on the same platform. Unified interface, central licence management and one partner for training, support and updates.

Request a combined offer
Contact

Request a demo or trial licence

We will demonstrate the CAAS Workstation to you personally, on-site or remotely.

  • Personal demo on-site or remote
  • Trial licences available
  • Training and support included