Clinical Software for Planning, Analysis and Diagnostics
Specialised software solutions for minimally invasive cardiac interventions, endovascular vascular surgery, interventional cardiology and cardiac diagnostics. Clinically validated, regulatory approved and proven in international routine use.
Preoperative Planning of Minimally Invasive Cardiac Interventions
For Heart Teams planning percutaneous valve interventions in a standardised and reproducible manner based on CT datasets.
3mensio Structural Heart guides the Heart Team from the first CT dataset to the final device selection. Seven specialised workflows with automated segmentation, Guided Reporting and fully manually adjustable measurements support precise planning of all common minimally invasive interventions as well as CTA-based coronary analysis.
- Transcatheter Aortic Valve Implantation (TAVI)
- Mitral valve repair and mitral valve replacement
- Tricuspid valve intervention
- Left Atrial Appendage Occlusion (LAAO)
- Percutaneous pulmonary valve replacement
- Valve-in-Valve and RedoTAV procedures
Aortic Valve
Guided TAVI planning workflow with automated determination of nadir points, virtual valve simulation, calcium assessment and assessment of all access routes.
Valve in Valve
Planning of RedoTAV and TAV-in-SAV procedures. Coronary Risk Plane and Neo Skirt Plane analysis for coronary obstruction risk assessment. Available as add-on licence to the Aortic module.
Mitral Valve
TMVr and TMVR planning. Automated annulus tracing in saddle and D-shape, Neo-LVOT screening, multimodality with 3D echo, septal crossing and virtual TEE and ICE planning.
Tricuspid Valve
Repair, replacement and transcaval intervention. Automated annulus tracing over the entire cardiac cycle, trabecular segmentation, automated volume measurements and positioning of the virtual device.
LAA
MSCT-guided LAAO planning with automated 3D segmentation, thrombus detection, septal crossing workflow and determination of optimal C-arm projections.
Pulmonary Valve
PPVI planning with three automated centrelines, polygon graph tool, virtual stent and coronary tracing to assess the relationship between coronary arteries and pulmonary trunk.
EVAR
Quantitative imaging analysis for abdominal aortic aneurysms. Automated centreline, 3D double oblique views and direct stent template integration with export of interactive iPAS reports.
TEVAR
Vessel measurement for thoracic aortic aneurysms. Analysis of supra-aortic vessels with dedicated branching vessel measurement tool and angulation assessment in the simulated angio view.
FEVAR
Workflow for planning fenestrated stent grafts with clock position display and precise analysis of vessel branches with regard to height and diameter.
Quantitative Imaging Analysis for Endovascular Vascular Surgery
Standardised and reproducible vessel measurement and stent graft selection for endovascular aortic procedures.
3mensio Vascular provides automated centreline detection, precise vessel measurement and integrated stent templates that adopt measurements directly. The structured workflow supports stent graft selection and generates print-ready order documents for EVAR, TEVAR and FEVAR.
View 3mensio VascularQuantitative Coronary Analysis and CTA-Based Pre-Planning
Functional stenosis assessment in the cardiac catheterisation laboratory and CT-based coronary analysis prior to the procedure.
The CAAS Workstation is the central analysis platform for coronary and peripheral arteries in the catheterisation laboratory. The integrated vFFR module calculates the pressure drop in the coronary artery based on two standard angiograms, without pressure wire and without adenosine. Manufacturer-independent and compatible with most X-ray systems. CTA-based coronary analysis and calcium scoring are available as a dedicated module in 3mensio Structural Heart.
- vFFR calculation without pressure wire and without adenosine
- QCA and QVA quantification of coronary and peripheral arteries
- LVA and RVA ventricular analysis
- IV LINQ co-registration with IVUS and OCT
- StentEnhancer visualisation
- CTA-based coronary analysis and calcium scoring
vFFR
Angiography-based functional lesion assessment from two standard angiograms, without pressure wire and without adenosine. Clinically validated by the multicentre randomised FAST III study with 2,235 patients at 37 centres (NEJM 2026).
QCA · QVA · LVA · RVA
Quantitative analysis of coronary and peripheral arteries as well as left and right ventricle. For use in the cardiac catheterisation laboratory and in clinical research. Multiple analyses simultaneously possible.
Coronary and Calcium Scoring
CTA-based coronary analysis with automated segmentation, stenosis quantification, simulated angio view and reproducible calcium scoring incl. Agatston Score.
VMS+ 4.0
3D reconstruction of all four cardiac chambers from the standard 2D echocardiogram. Volumetric measurements at MRI level in under five minutes, without tracing, without MRI appointment. FDA cleared and CE certified.
Qardia
Complete quantitative evaluation of transthoracic 2D echocardiographies in the browser. Ejection fraction, myocardial strain, diastolic function and valve function, without local installation.
MR Solutions
MRI-based cardiac analysis with workflows for 4D flow, functional analysis and tissue characterisation, 2D flow and myocardial strain quantification.
Quantitative Cardiac Diagnostics from Echo and MRI
Volumetric cardiac analysis from echocardiography, MRI or a combination of both modalities.
Ventripoint VMS+ 4.0 provides volumetric measurements of all four cardiac chambers directly from the standard 2D echocardiogram, without MRI. CAAS Qardia enables complete quantitative echocardiography evaluation in the browser. CAAS MR Solutions complements the portfolio for MRI-based functional and flow analyses.
Request a demo or trial licence
All software solutions are available for a personal demo on-site or remotely. Trial licences are provided on request.
- Personal demo on-site or remote
- Trial licences available for all software products
- Individual consultation with our software team