Ventripoint VMS+ 4.0

MRI accuracy from standard echo

3D cardiac analysis of all four chambers in under five minutes

VMS+ 4.0 generates a precise 3D model of the heart from a standard 2D echocardiography and provides volumetric measurements for all four cardiac chambers with an accuracy equivalent to that of a cardiac MRI. No additional MRI appointment, no anaesthesia and no contrast agent required.

< 5 min
Analysis time per examination
MRI level
Clinically proven accuracy
60+
Peer-reviewed publications
FDA and CE
Approved medical device
Ventripoint VMS+ 4.0 hardware sensor and workstation
VMS+ 4.0 System
VMS+ 4.0 · The System

AI assisted 3D reconstruction from 2D echo

The VMS+ 4.0 system combines a small sensor on the ultrasound probe with an intuitive software workstation. The proprietary KBR technology uses an extensive MRI image database as a reference and reconstructs a complete 3D model of the heart from the anatomical landmarks of a standard 2D echo. The system delivers reliable results even without technically optimal images.

System features
  • Small sensor on the ultrasound probe, no separate imaging system required
  • Compatible with ultrasound devices from all manufacturers
  • Software installation on existing workstation possible
  • All study data remain in the institution’s own IT system and PACS
  • No contour tracing required, anatomical landmarks suffice
Measurement results
  • Volumes and ejection fraction of all four cardiac chambers
  • End-diastolic and end-systolic volume
  • 3D visualisation of cardiac chambers in various planes
  • Export as structured report and as raw data in CSV format
Request demo
Result · 3D Cardiac Model

The heart in 3D, calculated from your patient’s echo

From the placed landmarks, VMS+ 4.0 creates a complete, rotatable 3D model of the heart. All four chambers are displayed spatially and can be viewed from any perspective. The model forms the basis for the volumetric measurements and can be stored directly in the report.

Clinical benefit
  • Spatial understanding of complex anatomical relationships
  • Clear case discussion in the Heart Team and with patients
  • Direct comparison of follow-up examinations using the 3D model
  • Measurements remain consistent across different operators
Request demo
3D cardiac model from VMS+ 4.0
Ventripoint VMS+ 4.0 software interface on iMac
VMS+ 4.0 Software
Software · 3D Echo and MRI

One software for both imaging modalities

The VMS+ software runs on any standard workstation and processes both 2D echo images and 3D echo and MRI datasets. Institutions that already have MRI data can import these directly and receive reproducible volumetric analyses regardless of the image source.

Software functions
  • 3D modelling from 2D echo, 3D echo or MRI images
  • No tracing required, only anatomical landmarks
  • Reliable analysis even with suboptimal image quality
  • Direct comparison between follow-up examinations
  • PACS integration and structured report export

“VMS+ not only gives us a very precise spatial view of complex congenital malformations at any time, but it also provides us with important data on the function of the heart muscle.”

Dr. Saleha Kabir — Lead Physiologist in Paediatrics and Advanced Echocardiography
Request demo
Workflow

Complete cardiac analysis in four steps

From echocardiography to validated 3D findings in under five minutes.

01

Echocardiography

Standard 2D echocardiography with the existing ultrasound equipment, without a special protocol and without any additional device other than the VMS+ sensor on the probe.

02

Place landmarks

Placement of anatomically relevant points on the echo images. No tracing and no manual contouring. This step takes only a few minutes.

03

3D analysis

The KBR technology automatically creates a complete 3D model of the heart and calculates volumes and ejection fractions of all four chambers.

04

Report and export

Structured findings report with all parameters, export of raw data in CSV format and storage of all study data on PACS.

Indications

Validated in complex cardiac conditions

VMS+ 4.0 has been clinically validated in patients with congenital heart defects, acquired heart disease and pulmonary hypertension. In international studies, including at the Mayo Clinic, results correlated closely with cMRI measurements and remained consistent across different operators — even with limited echo image quality.

Ventripoint VMS+ 3D cardiac model in Tetralogy of Fallot
Ventripoint VMS+ 3D cardiac model with RV to PA conduit
Ventripoint VMS+ 3D cardiac model with RV to PA conduit, second view
Ventripoint VMS+ 3D cardiac model after Rastelli repair
Ventripoint VMS+ 3D cardiac model in pulmonary hypertension
Ventripoint VMS+ 3D cardiac model in Ebstein's anomaly
Ventripoint VMS+ 3D cardiac model with double outlet right ventricle
Further portfolio

Cardiovascular software solutions from a single source

Ventripoint VMS+ 4.0 complements our portfolio for cardiovascular diagnostics and therapy planning. For interventional cardiology, structural heart medicine and endovascular vascular surgery, we offer specialised planning modules on proven platforms.

Clinically validated

Acquired and validated at Mayo Clinic, Duke University Hospital and DHZC Berlin

Mayo Clinic, Duke University Hospital and DHZC Berlin have acquired and validated VMS+ 4.0 for clinical use. The clinical accuracy is documented in international studies and published by Ventripoint Diagnostics.

Request demo